Wedron Silica 410

Toggle Error Bars:

Download data here: Wedron410.xlsx

Notes:

  • Measurement uncertainties at 95% confidence level are included in the downloadable MS. Excel file above
  • Detailed uncertainty analysis and error propagation methodology used to develop those measurement uncertainties is described in the Uncertainty Analysis page.

More information

Specific Heat Capacity (J/g-K)

  • Each data point shown in the plot is an average of four (4) up-ramp cycles/measurements of one sample
  • Instrument: NETZSCH STA 449 F3 Jupiter®
  • Purge gas: Argon
  • Protective gas: Argon
  • Sample mass: 83 mg